Specified to your build · Wires & Cables
Multi-Core Cable
Several conductors under one jacket, for runs that would otherwise need a bundle of single wires.
2 – 25
Cores
28 – 16 AWG
Conductor range
300 V
UL 2464 rating
Range and variants
A jacketed cable fixes the cores in a known geometry, which is what makes a consistent impedance, a consistent bend radius and a single part number possible. The jacket material, not the copper, decides where the cable can be used.
Unshielded
Control and power runs where no interference source is nearby.
Foil shielded
Drain wire plus foil, for signal runs inside a noisy cabinet.
Braid shielded
Better at high frequency and under repeated flexing than foil.
What has to be specified
The values that decide whether the part fits, before price or lead time are discussed.
- Core count
- 2 to 25 cores in common constructions.
- Conductor
- Stranded tinned copper, 28 to 16 AWG.
- Voltage rating
- 300 V on UL 2464.
- Jacket
- PVC standard, PUR for oil and abrasion.
- Shielding
- Unshielded, overall foil, or foil plus braid.
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where this is used
Control and signal runs
Multi-conductor cable between a controller and a machine section.
Panel-to-panel links
Where several circuits travel the same route and a loose bundle is not acceptable.
Sensor and actuator groups
Cores that stay together from the cabinet out to the field.
Questions that come up before ordering
01 When is a jacketed cable better than a bundle of single wires? Selection
When the run has to be one part number, one bend radius and one impedance. A jacket fixes the geometry, which a loose bundle cannot do.
02 Foil or braid shield? Shielding
Foil is cheaper and good at low frequency, but it is fragile under flexing. Braid survives movement and works higher up the spectrum, usually combined with foil.
03 Does the jacket material matter electrically? Jacket
Not directly. It decides where the cable can be used — PVC indoors, PUR where there is oil, abrasion or washdown.
04 Can cores be different sizes in one cable? Custom
Yes, as a composite construction. It is ordered as a custom build rather than picked from a standard list.
Need multi-core cable specified to your build?
Send the drawing, the environment and the interface. We confirm the open points before quoting, so the part you receive is the part that was specified.
- Drawing review before quote
- Prototype to volume
- Certifications on request