Specified to your build · Terminals

Ferrules

A thin tube crimped over the end of a stranded conductor, so the strands cannot spread when the clamp closes.

26 – 6 AWG

Wire range

8 – 20 mm

Length

Single / twin

Entry

Terminals · Ferrules
Ring, fork, pin, splice and disconnect terminals — insulated or bare, on reel or loose.
01 Range

Range and variants

Ferrules are mandatory in many terminal blocks and optional in others, which is why the same panel can contain both. The colour code follows the wire range, so a wrong ferrule is visible before the wire is inserted.

01

Single ferrule

The default for one conductor per clamp position.

02

Twin ferrule

Two conductors into one terminal block position.

03

Insulated ferrule

A colour-coded sleeve that also covers the crimp.

02 Specification

What has to be specified

The values that decide whether the part fits, before price or lead time are discussed.

Wire range
26 to 6 AWG, colour-coded by size.
Entry
Single entry, or twin entry for two conductors.
Length
8 to 20 mm, matched to the clamp depth.
Material
Electrolytic copper, tin plated.
Crimp
Trapezoid or square profile, with the specified tool.
03 Manufacturing

How the build is controlled

The same process controls run on every build, whether it is a prototype run or a repeat order.

01

IQC incoming control

Dedicated IQC staff inspect incoming materials and retain inspection records.

02

In-process inspection

First-article confirmation, patrol inspection, and SPC process monitoring.

03

MES traceability

MES covers the entire process flow, so any anomaly is located and handled fast.

04

8D closed-loop response

Agreed response times and internal escalation paths — clear ownership, fast resolution.

Locked process parameters
Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
Outgoing control
OQC inspection and mix-prevention packaging standards control outbound quality.
Compliance documents
Certifications and test reports available on demand for compliance audits.
Factory visits
Book a tour and walk the production floor along our visitor route.
04 Applications

Where this is used

Terminal blocks and spring clamps

Where a stranded conductor enters a clamp and has to stay consolidated.

Control panel wiring

The standard finish on every wire end in a panel build.

Two conductors into one terminal

Twin-entry ferrules where a single clamp position takes two wires.

06 FAQ

Questions that come up before ordering

01 Are ferrules mandatory? Compliance

In many terminal blocks, yes. In others they are optional, which is why the same panel can contain both. The block standard says which.

02 What does the colour code mean? Selection

The wire range. It is a visual check that the right ferrule went onto the right conductor, before the wire is inserted.

03 Trapezoid or square crimp? Tooling

Both are accepted profiles, and the tool and the ferrule have to match. What matters is the crimp height, not the shape.

04 Twin ferrule or two single ferrules? Application

Twin, where one clamp position takes two conductors. Two singles in one position is a connection the block was not tested for.

Need ferrules specified to your build?

Send the drawing, the environment and the interface. We confirm the open points before quoting, so the part you receive is the part that was specified.

  • Drawing review before quote
  • Prototype to volume
  • Certifications on request