Ferrules
A thin tube crimped over the end of a stranded conductor, so the strands cannot spread when the clamp closes.
26 – 6 AWG
Wire range
8 – 20 mm
Length
Single / twin
Entry
Range and variants
Ferrules are mandatory in many terminal blocks and optional in others, which is why the same panel can contain both. The colour code follows the wire range, so a wrong ferrule is visible before the wire is inserted.
Single ferrule
The default for one conductor per clamp position.
Twin ferrule
Two conductors into one terminal block position.
Insulated ferrule
A colour-coded sleeve that also covers the crimp.
What has to be specified
The values that decide whether the part fits, before price or lead time are discussed.
- Wire range
- 26 to 6 AWG, colour-coded by size.
- Entry
- Single entry, or twin entry for two conductors.
- Length
- 8 to 20 mm, matched to the clamp depth.
- Material
- Electrolytic copper, tin plated.
- Crimp
- Trapezoid or square profile, with the specified tool.
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where this is used
Terminal blocks and spring clamps
Where a stranded conductor enters a clamp and has to stay consolidated.
Control panel wiring
The standard finish on every wire end in a panel build.
Two conductors into one terminal
Twin-entry ferrules where a single clamp position takes two wires.
Questions that come up before ordering
01 Are ferrules mandatory? Compliance
In many terminal blocks, yes. In others they are optional, which is why the same panel can contain both. The block standard says which.
02 What does the colour code mean? Selection
The wire range. It is a visual check that the right ferrule went onto the right conductor, before the wire is inserted.
03 Trapezoid or square crimp? Tooling
Both are accepted profiles, and the tool and the ferrule have to match. What matters is the crimp height, not the shape.
04 Twin ferrule or two single ferrules? Application
Twin, where one clamp position takes two conductors. Two singles in one position is a connection the block was not tested for.
Need ferrules specified to your build?
Send the drawing, the environment and the interface. We confirm the open points before quoting, so the part you receive is the part that was specified.
- Drawing review before quote
- Prototype to volume
- Certifications on request