Built to specification · Cable Assemblies
BNC Cable Assemblies
Coaxial links for test equipment, video, sensors and instrumentation — where the impedance and the connector termination decide the signal, not the conductor alone.
50 / 75 Ω
Impedance
BNC / SMA
Connector
Coaxial
Construction
Choose the BNC assembly.
Impedance comes first, then the cable type, then the connector termination style.
A BNC connector is available for several cable types and both common impedances. The connector has to match the cable, and the cable has to match the system impedance.
The system impedance is fixed by the equipment, not by the cable you have.
50 Ω
Test equipment, RF, laboratory instruments and most signal sources.
75 Ω
Video, broadcast and certain sensor feeds.
Adapter leads
Between two systems where the impedance is defined at each end.
Mismatching 50 Ω and 75 Ω parts produces reflections that are invisible on a continuity test but visible on the signal.
What a BNC assembly quotation needs
Coaxial projects are defined by impedance, cable type and connector termination.
Impedance
50 Ω or 75 Ω, matching the equipment at both ends.
Cable type
The coaxial cable construction, which decides the connector series that fits.
Connectors
BNC or another coaxial interface, and the termination method.
Length
Nominal length and the loss the link can tolerate at the operating frequency.
Flexibility
Bench use with repeated handling, or a fixed installation.
Marking
Labelling for identification where several links run together.
If the instrument specifies a cable type, that specification governs — the connector must match the cable, not the other way round. See the RS232 family
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where to go next
Ethernet Cables
Network links built for the factory floor rather than the office — where the jacket, the connector coding and the bend radius decide whether the link stays up.
ReadRS232 Cables
Serial links for instruments, scales, controllers and legacy equipment — where the wiring is either straight-through or null-modem, and getting it wrong means no communication.
ReadM8 Cables
Compact circular cordsets for proximity switches, photoelectric sensors and small I/O devices — where the connector is smaller than the cable gland it replaces.
ReadM12 Cables
The workhorse circular connector of industrial automation — sensors, actuators, junction blocks, fieldbus and Ethernet all pass through an M12 interface.
ReadM16 Cables
A larger circular interface for runs that carry more contacts or more current than an M8 or M12 body allows, while keeping a sealed screw-locked connection.
ReadCustom wire harnesses
Where no standard family fits, multi-branch harnesses are built from the drawing.
ReadQuestions that come up before ordering
01 50 or 75 ohm — which one? Impedance
The impedance of the equipment, not the cable on the shelf. Video and broadcast runs are 75 ohm, test and RF equipment is usually 50 ohm, and mixing the two creates a reflection at the joint.
02 Crimp or solder centre contact? Termination
Crimp is the default for repeat builds because the joint can be inspected and pulled. Solder is used where the connector style or the field repair route requires it.
03 Can the assembly be built to a specific electrical length? Tolerance
Yes. Where phase matters, the lead is cut to a measured electrical length and the two ends are matched within the tolerance stated on the drawing.
04 What is supplied with each batch? Documentation
Impedance, connector type and length are recorded for the run, and the inspection record can be issued with the shipment on request.
Need BNC Cables to a specific length?
Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.