Built to specification · Cable Assemblies
RS232 Serial Cable Assemblies
Serial links for instruments, scales, controllers and legacy equipment — where the wiring is either straight-through or null-modem, and getting it wrong means no communication.
DB9 / DB25
Connector
9 – 25 way
Contact count
Straight or null-modem
Wiring
Choose the serial configuration.
The first question is whether the link is straight-through or crossed. The second is what connector each device uses.
RS232 has no negotiation. The cable either matches the device pinouts or it does not work. Most projects are solved by confirming the two device pinouts before building.
Straight-through or null-modem — the difference decides whether the link works at all.
Straight-through
Pin 2 to pin 2 and pin 3 to pin 3, for DTE-to-DCE connections.
Null-modem
Transmit and receive crossed, with handshake lines looped as the devices require.
Partial handshake
Where one device does not implement the full handshake and lines must be jumpered.
A null-modem cable is not a universal fix. Check whether each device is DTE or DCE before deciding to cross the lines.
What an RS232 cable quotation needs
Serial projects are settled by the pinouts. Everything else is mechanical.
Device pinouts
The connector and pin assignment at each end, from the device manuals.
Wiring type
Straight-through, null-modem, or a specific handshake arrangement.
Connectors
DB9 or DB25, male or female, with the shell and locking hardware.
Length
Nominal length — RS232 is limited by capacitance, so long runs need checking.
Shielding
Whether a shielded cable and a defined ground connection are needed.
Environment
Fixed or moving installation, and any fluid or abrasion exposure.
Send both device manuals or the pinout pages and the cable is fully defined — no drawing needed. See the BNC family
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where to go next
Ethernet Cables
Network links built for the factory floor rather than the office — where the jacket, the connector coding and the bend radius decide whether the link stays up.
ReadBNC Cables
Coaxial links for test equipment, video, sensors and instrumentation — where the impedance and the connector termination decide the signal, not the conductor alone.
ReadM8 Cables
Compact circular cordsets for proximity switches, photoelectric sensors and small I/O devices — where the connector is smaller than the cable gland it replaces.
ReadM12 Cables
The workhorse circular connector of industrial automation — sensors, actuators, junction blocks, fieldbus and Ethernet all pass through an M12 interface.
ReadM16 Cables
A larger circular interface for runs that carry more contacts or more current than an M8 or M12 body allows, while keeping a sealed screw-locked connection.
ReadCustom wire harnesses
Where no standard family fits, multi-branch harnesses are built from the drawing.
ReadQuestions that come up before ordering
01 Straight-through or null-modem? Wiring
Null-modem crosses transmit and receive so two DTE devices can talk. Straight-through connects DTE to DCE. The wiring is defined on the drawing and marked on the lead.
02 Can only the signal lines be wired? Configuration
Yes. Handshake lines are populated only where the device needs them, which is common when the far end is a simple controller rather than a modem.
03 How is the shield handled in a moulded lead? Shielding
The shield is bonded to the connector shell at one or both ends depending on the drawing. Bonding both ends is avoided where a ground loop would be created.
04 What is supplied with each batch? Documentation
Pin-to-pin assignment, length and connector gender are recorded for the run, and the inspection record can be issued with the shipment on request.
Need RS232 Cables to a specific length?