Built to specification · Cable Assemblies

M16 Cable Assemblies

A larger circular interface for runs that carry more contacts or more current than an M8 or M12 body allows, while keeping a sealed screw-locked connection.

2 – 24 pole

Contacts

IP67 mated

Protection

Solder or crimp

Termination

Sealed circular connectors with screw locking prepared for cable assembly
Circular connector reference sample. Contact arrangement follows the device interface.
01 Build options

Where M16 is the right interface.

M16 is chosen when M12 runs out of contacts or current, but a full rectangular housing would be excessive.

M16 sits between the compact sensor connectors and the heavy-duty rectangular housings. It is often chosen where a machine has to stay sealed but the circuit count has grown.

Where a single sealed connection has to carry a group of signals that would otherwise need two M12 runs.

01

Multi-pole signal bundles

Combined sensor, control and status signals in one sealed interface.

02

Machine module connections

Removable modules that need a single disconnect point for service.

03

Panel feed-throughs

Sealed entry from the field into an enclosure, with the cable side terminated.

Contact arrangement is not standardised across all M16 systems. Confirm the mating connector on the device before fixing the pinout.

02 Specification

What an M16 quotation needs

M16 systems vary more between manufacturers than M8 or M12, so the mating interface has to be pinned down first.

01

Mating interface

The device-side connector series and its contact arrangement.

02

Contact count

Number of contacts and whether any are dedicated to power or earth.

03

Current per contact

The load each contact carries, which decides the contact size.

04

Length and routing

Nominal length, fixed or moving installation, and the bend radius at each end.

05

Jacket

PVC or PUR, and the fluid or abrasion exposure along the route.

06

Sealing

IP rating required at the mated pair and at the panel entry.

If the device-side connector is not yet fixed, choosing a standard M12 or M8 interface usually shortens lead time. Compare M12 cables

03 Manufacturing

How the build is controlled

The same process controls run on every build, whether it is a prototype run or a repeat order.

01

IQC incoming control

Dedicated IQC staff inspect incoming materials and retain inspection records.

02

In-process inspection

First-article confirmation, patrol inspection, and SPC process monitoring.

03

MES traceability

MES covers the entire process flow, so any anomaly is located and handled fast.

04

8D closed-loop response

Agreed response times and internal escalation paths — clear ownership, fast resolution.

Locked process parameters
Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
Outgoing control
OQC inspection and mix-prevention packaging standards control outbound quality.
Compliance documents
Certifications and test reports available on demand for compliance audits.
Factory visits
Book a tour and walk the production floor along our visitor route.
05 FAQ

Questions that come up before ordering

01 When is M16 chosen over M12? Selection

When the contact count goes past what an M12 body can carry, or when the conductor size is too large for the smaller shell. M16 keeps the circular format while adding contacts and wire range.

02 Solder or crimp termination — which is specified? Termination

Crimp where the assembly is built in volume or the joint has to be inspected and reworked; solder where the contact density or the field repair route calls for it. The choice is recorded on the drawing.

03 Can the cable exit be angled? Mechanical

Yes. Straight and angled heads are both built, and the angle is fixed at moulding rather than added as an accessory afterwards.

04 What is supplied with each batch? Documentation

The contact layout, shell orientation and cable length are recorded for the run, and the inspection record can be issued with the shipment on request.

Need M16 Cables to a specific length?

Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.