Built to specification · Cable Assemblies
IEEE 1394 Cable Assemblies
FireWire links for machine vision cameras and legacy equipment, where the installed base still runs on 1394 and replacement assemblies have to match it exactly.
4 / 6 pin
Connector
400 / 800 Mbps
Link class
Shielded pairs
Construction
Choose the 1394 configuration.
The connector at each end is the whole specification in most cases — the interface itself is fixed.
IEEE 1394 is no longer a mainstream interface, but plenty of installed equipment still uses it. The requirement is usually a faithful replacement with the same connector and locking behaviour.
Pin count identifies the variant and the power capability.
4-pin
Data only, no power — common on compact cameras.
6-pin
Data plus power, with locking screws on most variants.
9-pin
The later variant with additional power and a different shell.
Locking screws on the 6-pin and 9-pin variants are there for a reason. On moving equipment, an unlocked 1394 connector works loose.
What a 1394 assembly quotation needs
Replacement projects need the original assembly as a reference; new projects need the device interfaces.
Connectors
Pin count and gender at each end, plus locking style.
Length
Nominal length — 1394 has practical length limits that affect the link.
Orientation
Straight or right-angle at each end.
Power conductors
Whether the assembly carries power, which decides the conductor size.
Shielding
Whether the original had a shield and drain, and how it was terminated.
Reference sample
A photo or the original assembly if the goal is a drop-in replacement.
For legacy replacement, a photo of both connectors and the overall length is usually enough to quote. See the USB family
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where to go next
OBD Diagnostic Cables
J1962 16-pin assemblies for scan tools, telematics devices, test benches and programming adapters — where pinout accuracy decides whether the tool connects at all.
ReadUSB Cables
USB links built into equipment rather than sold as accessories — where retention, bend life and panel mounting matter more than the retail finish.
ReadLVDS Cables
Controlled-impedance differential links between a display or camera module and its processing board, where the termination decides whether the image is stable.
ReadRibbon Cables
Flat cable assemblies for internal board-to-board links, where a low profile and a repeatable mass-terminated connection matter more than ruggedness.
ReadHSD Cables
Shielded differential assemblies for camera, display and infotainment links in vehicles and machines, built around the HSD connector system.
ReadSATA Cables
Internal storage links for equipment, industrial PCs and test systems — where the connector latch and the bend radius decide whether the drive stays connected.
ReadQuestions that come up before ordering
01 Which connector variant is specified? Selection
The 4-pin version carries the data pairs without power, the 6-pin adds the supply pair, and the 9-pin version serves the higher-rate link. The device port decides the variant.
02 Can a 4-pin device be fed from a 6-pin port? Compatibility
Yes, with an adaptor lead that carries the data pairs and leaves the supply pair unconnected. The adaptor is built to the same pair construction as the parent lead.
03 How are the pairs kept stable? Signal
Pair construction, twist and shield termination are fixed at assembly, and the pair length is matched across the run so skew stays inside the link budget.
04 What is supplied with each batch? Documentation
Connector variant, length and pair assignment are recorded for the run, and the inspection record can be issued with the shipment on request.
Need IEEE 1394 Cables to a specific length?
Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.