Built to specification · Cable Assemblies

IEEE 1394 Cable Assemblies

FireWire links for machine vision cameras and legacy equipment, where the installed base still runs on 1394 and replacement assemblies have to match it exactly.

4 / 6 pin

Connector

400 / 800 Mbps

Link class

Shielded pairs

Construction

Cable assemblies with connectors prepared for machine vision equipment
Assembly reference sample. Connector style follows the installed equipment.
01 Build options

Choose the 1394 configuration.

The connector at each end is the whole specification in most cases — the interface itself is fixed.

IEEE 1394 is no longer a mainstream interface, but plenty of installed equipment still uses it. The requirement is usually a faithful replacement with the same connector and locking behaviour.

Pin count identifies the variant and the power capability.

01

4-pin

Data only, no power — common on compact cameras.

02

6-pin

Data plus power, with locking screws on most variants.

03

9-pin

The later variant with additional power and a different shell.

Locking screws on the 6-pin and 9-pin variants are there for a reason. On moving equipment, an unlocked 1394 connector works loose.

02 Specification

What a 1394 assembly quotation needs

Replacement projects need the original assembly as a reference; new projects need the device interfaces.

01

Connectors

Pin count and gender at each end, plus locking style.

02

Length

Nominal length — 1394 has practical length limits that affect the link.

03

Orientation

Straight or right-angle at each end.

04

Power conductors

Whether the assembly carries power, which decides the conductor size.

05

Shielding

Whether the original had a shield and drain, and how it was terminated.

06

Reference sample

A photo or the original assembly if the goal is a drop-in replacement.

For legacy replacement, a photo of both connectors and the overall length is usually enough to quote. See the USB family

03 Manufacturing

How the build is controlled

The same process controls run on every build, whether it is a prototype run or a repeat order.

01

IQC incoming control

Dedicated IQC staff inspect incoming materials and retain inspection records.

02

In-process inspection

First-article confirmation, patrol inspection, and SPC process monitoring.

03

MES traceability

MES covers the entire process flow, so any anomaly is located and handled fast.

04

8D closed-loop response

Agreed response times and internal escalation paths — clear ownership, fast resolution.

Locked process parameters
Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
Outgoing control
OQC inspection and mix-prevention packaging standards control outbound quality.
Compliance documents
Certifications and test reports available on demand for compliance audits.
Factory visits
Book a tour and walk the production floor along our visitor route.
05 FAQ

Questions that come up before ordering

01 Which connector variant is specified? Selection

The 4-pin version carries the data pairs without power, the 6-pin adds the supply pair, and the 9-pin version serves the higher-rate link. The device port decides the variant.

02 Can a 4-pin device be fed from a 6-pin port? Compatibility

Yes, with an adaptor lead that carries the data pairs and leaves the supply pair unconnected. The adaptor is built to the same pair construction as the parent lead.

03 How are the pairs kept stable? Signal

Pair construction, twist and shield termination are fixed at assembly, and the pair length is matched across the run so skew stays inside the link budget.

04 What is supplied with each batch? Documentation

Connector variant, length and pair assignment are recorded for the run, and the inspection record can be issued with the shipment on request.

Need IEEE 1394 Cables to a specific length?

Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.