Built to specification · Cable Assemblies

M12 Cable Assemblies

The workhorse circular connector of industrial automation — sensors, actuators, junction blocks, fieldbus and Ethernet all pass through an M12 interface.

A / B / D / X

Coding

4 – 8 pole

Contacts

PUR or PVC

Jacket

M12 circular connectors and cable assemblies on a workbench
Connector reference sample. Coding, pole count and length follow the device specification.
01 Build options

Choose the M12 configuration.

Coding decides what the connector can carry. Pole count, head style and jacket follow from the installation.

Coding is the first thing to fix. A-coded carries discrete and analogue signals, D- and X-coded carry Ethernet, B-coded serves certain fieldbus systems. The coding must match the device, not the cable you prefer.

The general-purpose coding for discrete sensors, actuators and analogue devices.

01

4 and 5 pole

The most common sensor and actuator configurations, with or without a functional earth.

02

8 pole

Where several signals share one connector, such as compact I/O modules.

03

Junction leads

Multi-port blocks consolidated into a single trunk cable run back to the cabinet.

Mixing codings between cable and device is a common source of commissioning delay. Confirm the device interface before ordering.

02 Specification

What an M12 quotation needs

The coding and the device interface do most of the work. The rest is length, jacket and identification.

01

Coding

A, B, D, X or a power coding — and the device it connects to.

02

Pole count and gender

4, 5 or 8 pole, male or female, and whether both ends are terminated.

03

Head style

Straight or angled, overmoulded or field-wired.

04

Length

Nominal length, plus whether the run is fixed or moving.

05

Jacket and shielding

PVC or PUR, and whether shielding is required for the signal or the environment.

06

Rating

Voltage, current per contact and the IP rating the mated pair must hold.

For Ethernet versions, confirm the category the link has to support — Cat5e and Cat6a constructions are not interchangeable at gigabit rates. See the Ethernet family

03 Manufacturing

How the build is controlled

The same process controls run on every build, whether it is a prototype run or a repeat order.

01

IQC incoming control

Dedicated IQC staff inspect incoming materials and retain inspection records.

02

In-process inspection

First-article confirmation, patrol inspection, and SPC process monitoring.

03

MES traceability

MES covers the entire process flow, so any anomaly is located and handled fast.

04

8D closed-loop response

Agreed response times and internal escalation paths — clear ownership, fast resolution.

Locked process parameters
Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
Outgoing control
OQC inspection and mix-prevention packaging standards control outbound quality.
Compliance documents
Certifications and test reports available on demand for compliance audits.
Factory visits
Book a tour and walk the production floor along our visitor route.
05 FAQ

Questions that come up before ordering

01 Which coding does my device need? Coding

A-coded carries discrete and analogue signals, D- and X-coded carry Ethernet, B-coded serves certain fieldbus systems. The device interface decides the coding, not the cable that is easiest to stock.

02 Can different codings ship in one batch? Ordering

Yes. Each cordset is its own line on the drawing, so mixed codings, pole counts and lengths can be released together as one delivery.

03 How is the shield terminated? Shielding

The shield is bonded to the coupling nut or to a dedicated drain contact depending on the coding. The termination is defined on the drawing rather than left to the assembly station.

04 What is supplied with each batch? Documentation

Pinout, length and coding are recorded against the drawing for the run, and the inspection record can be issued with the shipment on request.

Need M12 Cables to a specific length?

Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.