Built to specification · Cable Assemblies
SATA Cable Assemblies
Internal storage links for equipment, industrial PCs and test systems — where the connector latch and the bend radius decide whether the drive stays connected.
7 pin
Data segment
15 pin
Power segment
Latching
Retention
Choose the SATA configuration.
Data and power are separate connectors on the drive. Most projects need one or both, with the right angle for the enclosure.
SATA assemblies are short and inexpensive, but a drive that drops out under vibration is an expensive fault. Latching connectors and strain relief are the usual fix.
Seven-conductor links with the impedance and shielding the interface expects.
Straight data cables
The default where there is clearance behind the drive.
Right-angle versions
For tight enclosures where a straight connector would foul the chassis.
Latching connectors
Where vibration or handling could otherwise work the connector loose.
SATA data cables carry a defined impedance and pair geometry. Substituting a general-purpose cable for a data link is a common cause of intermittent drives.
What a SATA assembly quotation needs
These are simple assemblies, but the mechanical detail is what the specification has to cover.
Connector types
Data, power or combined, with the angle required at each end.
Length
Nominal length — SATA is short-run by design, so tolerance matters.
Latching
Whether the connectors must latch, and which end.
Routing
Bend radius and any tight turn behind the drive bay.
Shielding
Whether the data link needs shielding for the enclosure environment.
Quantity
Volume per build, and whether the assembly repeats identically.
If the drive and the backplane are fixed, send both connector part numbers — the assembly is then fully defined. See the IEEE 1394 family
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where to go next
OBD Diagnostic Cables
J1962 16-pin assemblies for scan tools, telematics devices, test benches and programming adapters — where pinout accuracy decides whether the tool connects at all.
ReadUSB Cables
USB links built into equipment rather than sold as accessories — where retention, bend life and panel mounting matter more than the retail finish.
ReadLVDS Cables
Controlled-impedance differential links between a display or camera module and its processing board, where the termination decides whether the image is stable.
ReadRibbon Cables
Flat cable assemblies for internal board-to-board links, where a low profile and a repeatable mass-terminated connection matter more than ruggedness.
ReadHSD Cables
Shielded differential assemblies for camera, display and infotainment links in vehicles and machines, built around the HSD connector system.
ReadIEEE 1394 Cables
FireWire links for machine vision cameras and legacy equipment, where the installed base still runs on 1394 and replacement assemblies have to match it exactly.
ReadQuestions that come up before ordering
01 Can data and power be combined in one lead? Configuration
Yes. Combined leads carry the 7-pin data segment and the 15-pin power segment in one jacket, with the branch point fixed at the drawing stage.
02 What length can the lead be built to? Signal
The lead is built to the length the enclosure allows. SATA has a defined signal budget, so long runs are specified with the host and device in mind rather than by picking the longest lead that fits.
03 Are right-angle connectors available on both ends? Mechanical
Straight and right-angle versions are both built, and the exit direction of each end is specified separately because the two ends usually leave in different directions.
04 What is supplied with each batch? Documentation
Connector orientation, length and segment assignment are recorded for the run, and the inspection record can be issued with the shipment on request.
Need SATA Cables to a specific length?
Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.