Built to specification · Cable Assemblies

SATA Cable Assemblies

Internal storage links for equipment, industrial PCs and test systems — where the connector latch and the bend radius decide whether the drive stays connected.

7 pin

Data segment

15 pin

Power segment

Latching

Retention

Fine-gauge conductors prepared for internal data and power cable assemblies
Conductor reference sample. Connector style follows the drive and backplane specification.
01 Build options

Choose the SATA configuration.

Data and power are separate connectors on the drive. Most projects need one or both, with the right angle for the enclosure.

SATA assemblies are short and inexpensive, but a drive that drops out under vibration is an expensive fault. Latching connectors and strain relief are the usual fix.

Seven-conductor links with the impedance and shielding the interface expects.

01

Straight data cables

The default where there is clearance behind the drive.

02

Right-angle versions

For tight enclosures where a straight connector would foul the chassis.

03

Latching connectors

Where vibration or handling could otherwise work the connector loose.

SATA data cables carry a defined impedance and pair geometry. Substituting a general-purpose cable for a data link is a common cause of intermittent drives.

02 Specification

What a SATA assembly quotation needs

These are simple assemblies, but the mechanical detail is what the specification has to cover.

01

Connector types

Data, power or combined, with the angle required at each end.

02

Length

Nominal length — SATA is short-run by design, so tolerance matters.

03

Latching

Whether the connectors must latch, and which end.

04

Routing

Bend radius and any tight turn behind the drive bay.

05

Shielding

Whether the data link needs shielding for the enclosure environment.

06

Quantity

Volume per build, and whether the assembly repeats identically.

If the drive and the backplane are fixed, send both connector part numbers — the assembly is then fully defined. See the IEEE 1394 family

03 Manufacturing

How the build is controlled

The same process controls run on every build, whether it is a prototype run or a repeat order.

01

IQC incoming control

Dedicated IQC staff inspect incoming materials and retain inspection records.

02

In-process inspection

First-article confirmation, patrol inspection, and SPC process monitoring.

03

MES traceability

MES covers the entire process flow, so any anomaly is located and handled fast.

04

8D closed-loop response

Agreed response times and internal escalation paths — clear ownership, fast resolution.

Locked process parameters
Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
Outgoing control
OQC inspection and mix-prevention packaging standards control outbound quality.
Compliance documents
Certifications and test reports available on demand for compliance audits.
Factory visits
Book a tour and walk the production floor along our visitor route.
05 FAQ

Questions that come up before ordering

01 Can data and power be combined in one lead? Configuration

Yes. Combined leads carry the 7-pin data segment and the 15-pin power segment in one jacket, with the branch point fixed at the drawing stage.

02 What length can the lead be built to? Signal

The lead is built to the length the enclosure allows. SATA has a defined signal budget, so long runs are specified with the host and device in mind rather than by picking the longest lead that fits.

03 Are right-angle connectors available on both ends? Mechanical

Straight and right-angle versions are both built, and the exit direction of each end is specified separately because the two ends usually leave in different directions.

04 What is supplied with each batch? Documentation

Connector orientation, length and segment assignment are recorded for the run, and the inspection record can be issued with the shipment on request.

Need SATA Cables to a specific length?

Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.