Built to specification · Cable Assemblies
DC Power Cable Assemblies
Low-voltage power leads for equipment, adapters and distribution — where the connector has to match the device, and the conductor has to match the load.
5.5 / 2.1 mm
Barrel size
Centre + / −
Polarity
Moulded or field
Termination
Choose the DC configuration.
The device connector decides the plug; the load decides the conductor; the environment decides the jacket.
DC connectors are far less standardised than they look. Barrel jack dimensions, polarity and locking style vary, and the wrong plug either does not fit or does not stay in.
The plug has to match the device socket exactly — diameter, length and polarity.
Barrel jacks
Common dimensions such as 5.5 × 2.1 mm and 5.5 × 2.5 mm, centre-positive or centre-negative.
Locking connectors
Screw-locked or bayonet DC connectors for equipment that must not be unplugged accidentally.
Terminal and lug ends
Ring terminals, ferrules or lugs for distribution and panel connections.
Polarity is not universal on barrel connectors. Confirm centre-positive or centre-negative against the device marking before building.
What a DC cable quotation needs
The connector dimensions and the current are the two values that cannot be guessed.
Connector dimensions
Plug outer and inner diameter, length, and polarity.
Operating current
Continuous current, which sets the conductor cross-section.
Voltage
Nominal voltage and the acceptable drop over the run length.
Length
Nominal length — long runs at low voltage lose a meaningful share of the supply.
Jacket
PVC or a more abrasion-resistant material for the installation.
Locking
Whether the connector must lock, and any strain relief at the device end.
If the current and the length are both known, check the voltage drop before fixing the conductor size. Run the voltage drop calculator
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where to go next
M8 Cables
Compact circular cordsets for proximity switches, photoelectric sensors and small I/O devices — where the connector is smaller than the cable gland it replaces.
ReadM12 Cables
The workhorse circular connector of industrial automation — sensors, actuators, junction blocks, fieldbus and Ethernet all pass through an M12 interface.
ReadM16 Cables
A larger circular interface for runs that carry more contacts or more current than an M8 or M12 body allows, while keeping a sealed screw-locked connection.
ReadCustom wire harnesses
Where no standard family fits, multi-branch harnesses are built from the drawing.
ReadQuestions that come up before ordering
01 How is polarity confirmed? Polarity
By the marking on the device and the plug barrel dimensions together. The centre conductor and the outer sleeve are wired to the polarity the device states, and the lead is marked accordingly.
02 Which barrel size is standard? Specification
5.5 mm outside with a 2.1 mm or 2.5 mm centre is the common pairing. The device socket decides, and the two dimensions are specified together because either alone is ambiguous.
03 Can the lead be built with a strain relief boot? Mechanical
Yes. Moulded boots and field-assembly versions are both built, and the boot length is chosen for the bend radius the installation allows.
04 What is supplied with each batch? Documentation
Barrel size, polarity and length are recorded for the run, and the inspection record can be issued with the shipment on request.
Need DC Cables to a specific length?
Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.