Built to specification · Cable Assemblies

LVDS Cable Assemblies

Controlled-impedance differential links between a display or camera module and its processing board, where the termination decides whether the image is stable.

100 Ω

Differential impedance

1 – 2 channel

Pair count

Shielded pairs

Construction

Fine-gauge wires and shielded pairs prepared for a differential cable assembly
Conductor reference sample. Pair geometry and impedance follow the interface specification.
01 Build options

Choose the LVDS configuration.

Display links, camera links and board-to-board links share the electrical requirement but differ in connector and mechanical build.

LVDS is a signalling standard, not a connector standard. The same electrical requirement appears behind many different connector shells, so the interface has to be specified separately from the pair geometry.

Panel-side connectors are usually fine-pitch and fixed by the panel, so the assembly follows the panel specification.

01

Panel-to-board assemblies

Fine-pitch connectors with micro-coaxial or twisted-pair constructions.

02

Long panel runs

Where the panel sits away from the driver board and skew becomes critical.

03

Backlight and control leads

Auxiliary conductors for backlight power and control signals in the same assembly.

Impedance, skew and shield termination have to be held through the connector, not only in the cable. A correct cable with a poor termination fails the same way as a wrong cable.

02 Specification

What an LVDS assembly quotation needs

These projects depend on the interface definition more than on the cable itself.

01

Interface specification

Pair count, impedance target and the connector at each end.

02

Connector part numbers

Board-side and panel-side connectors, including mating heights.

03

Length and routing

Nominal length, bend radius and whether the route moves.

04

Skew requirement

Intra-pair and inter-pair skew limits from the interface specification.

05

Shielding

Whether overall shielding and a defined ground return are required.

06

Mechanical build

Overmould, strain relief, folding and any space limit inside the enclosure.

Where the panel or module is already selected, its datasheet usually defines the pair count and connector — send it and the rest follows. See the HSD family

03 Manufacturing

How the build is controlled

The same process controls run on every build, whether it is a prototype run or a repeat order.

01

IQC incoming control

Dedicated IQC staff inspect incoming materials and retain inspection records.

02

In-process inspection

First-article confirmation, patrol inspection, and SPC process monitoring.

03

MES traceability

MES covers the entire process flow, so any anomaly is located and handled fast.

04

8D closed-loop response

Agreed response times and internal escalation paths — clear ownership, fast resolution.

Locked process parameters
Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
Outgoing control
OQC inspection and mix-prevention packaging standards control outbound quality.
Compliance documents
Certifications and test reports available on demand for compliance audits.
Factory visits
Book a tour and walk the production floor along our visitor route.
05 FAQ

Questions that come up before ordering

01 What decides whether an LVDS link works over a custom length? Signal

Impedance continuity, pair skew and shield termination. Each of the three is fixed at assembly, so the drawing has to state the pair construction rather than just the connector.

02 Can the pairs be terminated to a fine-pitch board connector? Termination

Yes. Board-side connectors are terminated to the pitch the device uses, with the drain and ground returns defined on the drawing.

03 How is skew controlled? Tolerance

Pairs are cut to matched length within the assembly and the pair-to-pair relationship is held across the run. The tolerance is stated on the drawing so it can be inspected.

04 What is supplied with each batch? Documentation

Pair construction, length and connector assignment are recorded for the run, and the inspection record can be issued with the shipment on request.

Need LVDS Cables to a specific length?

Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.