Specified to your build · Connectors
Sealed Rectangular Connectors
Multi-cavity housings that hold several circuits in one sealed body, used where a circular connector would be too large or the wrong shape.
2 – 12
Cavities per shell
IP67
Mated rating
20 – 12 AWG
Wire range
Range and variants
The seal is a system: a grommet at each wire, an interface seal at the mating face, and a cavity plug in every unused position. Leave one of the three out and the housing no longer holds its rating, even though the connector still mates.
Wire-to-panel
Flange-mounted receptacle with a defined panel cut-out and gasket.
Wire-to-wire inline
Two plugs mated in the run, for a joint that has to open in service.
Hybrid power and signal
Mixed cavity sizes in one shell, so one entry carries both.
What has to be specified
The values that decide whether the part fits, before price or lead time are discussed.
- Positions
- 2 to 12 cavities in common shells.
- Sealing
- IP67 mated, with grommet, interface seal and cavity plugs.
- Wire range
- 20 to 12 AWG by terminal series.
- Housing material
- PA66 with UV stabiliser, or PBT for higher temperature.
- Retention
- Latch, CPA and terminal position assurance.
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where this is used
Machine and panel wiring
Bulk connections through an enclosure wall where several circuits share one entry.
Outdoor and washdown equipment
Where the mated pair has to hold IP67 over the service life, not just at assembly.
Vehicle and off-highway
Housings with latch and CPA that survive sustained vibration.
Questions that come up before ordering
01 What are the three parts of the seal? Sealing
A grommet at each wire, an interface seal at the mating face, and a cavity plug in every empty position. Missing any one of them drops the rating even though the connector still mates.
02 Do unused cavities need plugs? Sealing
Yes. An open cavity is a hole through the housing. The plug is a line item on the drawing, and it is the item most often left off.
03 When is a rectangular connector better than circular? Selection
When several circuits share one entry and the space is flat rather than round — a panel wall, a machine frame. Circular wins where the entry has to rotate or the space is a drilled hole.
04 Does the latch survive vibration on its own? Retention
Not always. A latch plus CPA is the vehicle-grade answer; a latch alone is fine on a static machine.
Need sealed rectangular connectors specified to your build?
Send the drawing, the environment and the interface. We confirm the open points before quoting, so the part you receive is the part that was specified.
- Drawing review before quote
- Prototype to volume
- Certifications on request