Built to specification · Cable Assemblies
Industrial Ethernet Cable Assemblies
Network links built for the factory floor rather than the office — where the jacket, the connector coding and the bend radius decide whether the link stays up.
Cat5e / Cat6
Category
RJ45
Interface
UTP or shielded
Construction
Choose the Ethernet assembly.
Category sets the data rate. Connector coding and jacket set whether the link survives the environment.
A patch lead that works in a cabinet can fail on a moving gantry within weeks. Category, jacket and connector coding have to be specified against the installation, not just the data rate.
The required data rate and the existing network decide the category.
Cat5e
100 Mbit and 1 Gbit links over short runs — the common choice for device-level networks.
Cat6
Higher margin at 1 Gbit, with tighter pair and crosstalk requirements.
Cat6a
10 Gbit capability over the full channel length, with heavier construction.
Mixing coding between cable and device, or using a fixed-installation cable on a moving axis, are the two most common causes of link faults in the field.
What an Ethernet assembly quotation needs
Network projects need the category and the coding confirmed before the cable construction can be chosen.
Category
Cat5e, Cat6 or Cat6a, and the data rate the link must support.
Connectors
RJ45, M12 D-coded, M12 X-coded or a mixed assembly.
Length
Nominal length and the channel limit for the category in use.
Installation
Fixed, flexible or drag-chain, with the bend radius and travel if moving.
Environment
Oil, coolant, washdown or UV exposure along the route.
Shielding
Whether shielded cable and connectors are required, and where the shield is earthed.
For a device-level network, confirm whether the switch port and the device both accept the same coding before ordering either end. See the M12 family
How the build is controlled
The same process controls run on every build, whether it is a prototype run or a repeat order.
IQC incoming control
Dedicated IQC staff inspect incoming materials and retain inspection records.
In-process inspection
First-article confirmation, patrol inspection, and SPC process monitoring.
MES traceability
MES covers the entire process flow, so any anomaly is located and handled fast.
8D closed-loop response
Agreed response times and internal escalation paths — clear ownership, fast resolution.
- Locked process parameters
- Crimping, soldering, molding and waterproofing run on locked parameters with defined acceptance criteria.
- Outgoing control
- OQC inspection and mix-prevention packaging standards control outbound quality.
- Compliance documents
- Certifications and test reports available on demand for compliance audits.
- Factory visits
- Book a tour and walk the production floor along our visitor route.
Where to go next
RS232 Cables
Serial links for instruments, scales, controllers and legacy equipment — where the wiring is either straight-through or null-modem, and getting it wrong means no communication.
ReadBNC Cables
Coaxial links for test equipment, video, sensors and instrumentation — where the impedance and the connector termination decide the signal, not the conductor alone.
ReadM8 Cables
Compact circular cordsets for proximity switches, photoelectric sensors and small I/O devices — where the connector is smaller than the cable gland it replaces.
ReadM12 Cables
The workhorse circular connector of industrial automation — sensors, actuators, junction blocks, fieldbus and Ethernet all pass through an M12 interface.
ReadM16 Cables
A larger circular interface for runs that carry more contacts or more current than an M8 or M12 body allows, while keeping a sealed screw-locked connection.
ReadCustom wire harnesses
Where no standard family fits, multi-branch harnesses are built from the drawing.
ReadQuestions that come up before ordering
01 Which category has to be specified for an industrial run? Selection
The category the link is designed to, not the highest one available. Cat6 buys headroom for long or noisy runs; Cat5e is sufficient where the link budget is short and clean.
02 Is shielded cable needed? Shielding
Shielded construction is specified where the run passes drives, welding equipment or long parallel power cables. The shield has to be bonded at the enclosure to be worth anything.
03 Can the lead be built with a field-termination end? Configuration
Yes. One end can be left for field termination with a plug or a keystone jack, with the pair assignment marked on the lead.
04 What is supplied with each batch? Documentation
Category, length and pair assignment are recorded for the run, and the inspection record can be issued with the shipment on request.
Need Ethernet Cables to a specific length?
Send the connector part numbers, the length and the installation conditions. We confirm the open points and quote against the approved specification.